The tympanic membrane displacement analyser for monitoring intracranial pressure in children
dc.contributor.author | Gwer, Samson | |
dc.contributor.author | Sheward, Victoria | |
dc.contributor.author | Birch, Anthony | |
dc.contributor.author | Marchbanks, Robert | |
dc.contributor.author | Idro, Richard | |
dc.contributor.author | Newton, Charles | |
dc.contributor.author | Kirkham, Fenella | |
dc.contributor.author | Lin, Jean-Pierre | |
dc.contributor.author | Lim, Ming | |
dc.date.accessioned | 2013-09-27T12:51:25Z | |
dc.date.available | 2013-09-27T12:51:25Z | |
dc.date.issued | 2013-06 | |
dc.description | doi: 10.1007/s00381-013-2036-5 | en_US |
dc.description.abstract | Purpose: Raised intracranial pressure (ICP) is a potentially treatable cause of morbidity and mortality but tools for monitoring are invasive. We sought to investigate the utility of the tympanic membrane displacement (TMD) analyser for non-invasive measurement of ICP in children. Methods: We made TMD observations on normal and acutely comatose children presenting to Kilifi District Hospital (KDH) at the rural coast of Kenya and on children on follow-up for idiopathic intracranial hypertension at Evelina Children's Hospital (ECH), in London, UK. Results: We recruited 63 patients (median age 3.3 (inter-quartile range (IQR) 2.0-4.3) years) at KDH and 14 children (median age 10 (IQR 5-11) years) at ECH. We observed significantly higher (more negative) TMD measurements in KDH children presenting with coma compared to normal children seen at the hospital's outpatient department, in both semi-recumbent [mean −61.3 (95 % confidence interval (95 % CI) −93.5 to 29.1) nl versus mean −7.1 (95 % CI −54.0 to 68.3) nl, respectively; P = 0.03] and recumbent postures [mean −61.4 (95 % CI −93.4 to −29.3) nl, n = 59) versus mean −25.9 (95 % CI −71.4 to 123.2) nl, respectively; P = 0.03]. We also observed higher TMD measurements in ECH children with raised ICP measurements, as indicated by lumbar puncture manometry, compared to those with normal ICP, in both semi-recumbent [mean −259.3 (95 % CI −363.8 to −154.8) nl versus mean 26.7 (95 % CI −52.3 to 105.7) nl, respectively; P < 0.01] and recumbent postures [mean −137.5 (95 % CI −260.6 to −14.4) nl versus mean 96.6 (95 % CI 6.5 to 186.6) nl, respectively; P < 0.01]. Conclusion: The TMD analyser has a potential utility in monitoring ICP in a variety of clinical circumstances. | en_US |
dc.identifier.citation | Childs Nerv Syst. 2013 Jun;29(6):927-33 | en_US |
dc.identifier.uri | http://ir-library.ku.ac.ke/handle/123456789/7382 | |
dc.language.iso | en | en_US |
dc.publisher | Child's Nervous System | en_US |
dc.title | The tympanic membrane displacement analyser for monitoring intracranial pressure in children | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- The tympanic membrane....pdf
- Size:
- 290.91 KB
- Format:
- Adobe Portable Document Format
- Description:
- Full Text Article
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: